Average torque = 15.7Nm
Power(W) = 15.7Nm * 2 * pi * 10.1478 = 1kW
At worst-case bus voltage of 100V (worst-case according to the desmos graph on Robin’s page linked at the top), this gives 10A of bus current - but this is not useful for the output current calculations.
Vbus = 100V
Io = 10A
What if we have a 36km/h (10m/s) headwind - aero losses will increase, and thus the torque requirement and bus current will increase?