Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  •  relay footprint is wrong → increase the through hole size, pad size and distance between everything so it actually mates
  •  have a pin on the controller board get a high or low if connected to the right jumper config for 5 vs 6 mppt board
  •  none of the vias tented?? maybe manufacturing issue (this was not jlc) but double check pcb
  •  move C32 north so 12V isnt shorted to ground 😞
  •  switch mosi and clock and fix miso silk (says mso)
  •  reconfigure relay driver for low side output for current sinking IC
  •  indicator LED for 12V
  •  move the I2C pullup resistors to be near the controller board, not near the first mppt