Location | Length estimate equation | Length estimate total (m) | Cable Type |
---|---|---|---|
DC Motor Fuse → DC Rear panel connector | 50cm x 2 | 1 | 16mm2 |
DC Rear Panel Connector → DC Motor controller connector | 1.5m x2 | 3 | 16mm2 |
DC Motor Controller Connector → DC Motor Controller Lugs | 30cm x 2 | 0.6 | 16mm2 |
Phase Motor Contoller Lugs → Phase Motor Controller ConnectorSpeed Switch | 30cm x 3 | 0.9 | 10mm2 (we could use 16mm2 here if we want) |
Phase Speed Switch → Phase connector outputs | 30cm x6 | 1.8 | 10mm2 |
Phase Motor Controller Connector → Phase Motor Connector |
|
|
|
Total Requirement (for 1 car)
16mm2:
10mm2: 2 = (1+3+0.6) * 2 = 9.2m → order 30m?
10mm2 = (0.9+1.8) * 2 = 5.4m → order 20m?
Purchase List
Add 3x the amount of cable required to have lots for test setups and for repairs. 1.5 or 2x of other items should be fine.
Item | Details | Link | Min Qty | Purchase Qty |
---|---|---|---|---|
Crimp Lugs - DC Bus | 16mm2 Crimp | 4 | ||
Crimp Lugs - Motor Phase | 10mm2 Crimp | 6 | ||
Cable - Motor Phase | 8AWG / 10mm2 | Ask IEWC for options. | ||
Cable - DC Bus | 6AWG / 16mm2 | Ask IEWC for options. | ||
Jointing Compound | Link | 1 | ||
Red Heat Shrink Bus | Link | 1ft | ||
Black Heat Shrink Bus | Link | 1ft | ||
Heat Shrink Phase 1 | Link | 1ft | ||
Heat Shrink Phase 2 | Link | 1ft | ||
Heat Shrink Phase 3 | Link | 1ft |