-I need to attach some thermistors first…
...
I put a variety of them on so that we can estimate temperature accuracy over the full range:
Thermistor Cell Input number | Bottom Resistor Value | Expected Voltage (10k upper resistor, 3V0 ref) | Temperature Result Expected |
---|---|---|---|
0 | 10k | 1.5 | 25 |
1 | 3.3k | 0.74436 | 52 |
2 | 10k | 1.5 | 25 |
3 | 4.7k | 0.959186 | 43 |
4 | 10k | 1.5 | 25 |
5 | 5.1k | 1.013245 | 41 |
6 | 10k | 1.5 | 25 |
7 | 6.8k | 1.214285 | 34 |
8 | 10k | 1.5 | 25 |
9 | 10k pot | 0-1.5 | 25+ |
10 | 10k | 1.5 | 25 |
11 | 3.3k | 0.74436 | 52 |
12 | 4.7k | 0.959186 | 43 |
13 | 5.1k | 1.013245 | 41 |
14 | 6.8k | 1.214285 | 34 |
15 | 10k | 1.5 | 25 |
16 | 10k | 1.5 | 25 |
17 | 1.5@25C | 25 |