  • Check for continuity between cell inputs, balance inputs, 3 V, 5 V, fused VBAT+ and fused VBAT-. All of these nets should be isolated from each other.

  • Connect the BMS carrier to the AFE isoSPI port A.

  • Power the BMS carrier board with 12 V.

  • Connect the AFE to 12 cells in series, OR connect a power supply between VBAT+ and VBAT-. The power supply can be set to about 30 V with a current limit of about 100 mA.

  • Measure the voltage between 3 V and VBAT-, and 5 V and VBAT-. 3 V will only be powered when the LTC6811 is awake, so the LTC6811 needs to receive valid ADC commands over isoSPI every 2 s or the REFON bit can be set to 1 with the WRCFGA command, and then the 3 V net can be measured with a DMM. Otherwise, an oscilloscope can be used to measure the 3 V net after a valid ADC command is sent.

  • Turn off the power supply.

...