- Remove R23.
- Connect the E-load between the HSD side of the kill switch connector, and GND.
- Supply 12 V between GND and 12 V.
- Enable IN2 and DIAG_EN of the HSD (PB8 and PB9).
- Set the E-load to draw 100 mA. This will trigger the over-current protection feature of the HSD.
- Measure the voltage across D2. If it is 3.3 V or less, then R23 can be added.
- Turn off the power supply.
...