- Check for continuity between GND, 3.3 V, 5 V, and 12 V. All of these should be isolated from each other.
- Remove R23.
- Supply 12 V between GND and 12 V. A current limit of 100 mA should be sufficient for most testing. Switching the relays and/or fans will require more current (up to 4 A). Measure the voltage between GND and 3.3 V, and GND and 12 V.
- Set PB0 high to enable the 5 V converter. Measure the voltage between GND and 5 V.
- Connect an oscilloscope probe between GND and 5 V to measure the ripple of the 5 V converter.
- Turn off the power supply.
HSD Current Sense Output (TPS2H000-Q1)
- Remove R23.
- Connect the E-load between the HSD side of the kill switch connector, and GND.
- Supply 12 V between GND and 12 V.
- Enable IN2 and DIAG_EN of the HSD (PB8 and PB9).
- Set the E-load to draw 100 mA.
- Measure the voltage across D2. If it is 3.3 V or less, then R23 can be added.
- Turn off the power supply.
...