Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • Check for continuity between cell inputs, balance inputs, 3 V, 5 V, fused VBAT+ and fused VBAT-. All of these nets should be isolated from each other.

  • Connect the BMS carrier to the AFE isoSPI port A.

  • Connect the AFE to 12 cells in series, OR connect a power supply between VBAT+ and VBAT-. The power supply can be set to about 30 V with a current limit of about 100 mA.

  • Toggle the CS pin of the AFE isoSPI from the BMS carrier constantly with a delay of about 1 s.

  • Measure the voltage between 3 V and VBAT-, and 5 V and VBAT-.

  • Turn off the power supply.