Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Test Voltage output (regulated 19V~19V)

    1. Voltage Ripples

  2. Test

    Over-

    Input Voltage

    protection

    1. Test

    Input Voltage
    1. Lower and Upper end (8V and 16V)

    2. Voltage Ripples

  3. Test Current Draw (1A)

    1. Ensure at least 1A current draw as specified without heating issues

    2. Test Over-Current protection (draw ~10A)

    Check for overheating under load

    1. Monitor temp while testing

    2. (Optional) Over-temperature protectionEnsure normal operation range (~20W) without heating issues

    3. Ensure max power range (~65W) with reasonable temperature ranges

Test was conducted with a substitute load, will require a cooling element (In-progress). Testing with monitor is also in-progress.